The KM 184 is a state-of-the-art small diaphragm condenser microphone with a uniform, frequency-independent cardioid polar pattern. Its very natural, transparent sound with very low self-noise and high SPL capability have made the KM 184 a worldwide stage and studio standard for many applications ranging from classical piano to heavy metal drums..

The KM 184 is a state-of-the-art small diaphragm condenser microphone with a uniform, frequency-independent cardioid polar pattern. Its very natural, transparent sound with very low self-noise and high SPL capability have made the KM 184 a worldwide stage and studio standard for many applications ranging from classical piano to heavy metal drums.
Neumann KM184

Features:
– Uniform cardioid pattern without off-axis coloration
– Linear frequency response with a slight treble lift
– Very low self-noise (13 dB-A)
– Low impedance output for long cable runs without transmission losses
– Transformerless circuitry
– Compact size, visually unobtrusive

Please follow and like us:

Additional information

Color

,

DATA & DIAGRAMS

Acoustical operating principle Pressure gradient transducer
Directional Pattern Cardioid
Frequency Range 20 Hz … 20 kHz
Sensitivity at 1 kHz into 1 kohm 15 mV/Pa ± 1 dB
Rated Impedance 50 ohms
Rated load impedance 1 kohms
Equivalent noise level, CCIR 1 22 dB
Equivalent noise level, A-weighted 2 13 dB-A
Maximum SPL for THD 0.5% 3 138 dB
Signal-to-noise ratio, CCIR (re. 94 dB SPL) 4 72 dB
Signal-to-noise ratio, A-weighted (re. 94 dB SPL) 5 81 dB
Maximum output voltage 10 dBu
Supply voltage (P48, IEC 61938) 48 V ± 4 V
Current consumption (P48, IEC 61938) 3.2 mA
Matching connector XLR 3 F
Weight approx. 80 g
Diameter 22 mm
Length 107 mm
1) according to IEC 60268-1; CCIR-weighting acccording to CCIR 468-3, quasi peak; A-weighting according to IEC 61672-1, RMS
2) according to IEC 60268-1; CCIR-weighting acccording to CCIR 468-3, quasi peak; A-weighting according to IEC 61672-1, RMS
3) measured as equivalent el. input signal
4) according to IEC 60268-1; CCIR-weighting acccording to CCIR 468-3, quasi peak; A-weighting according to IEC 61672-1, RMS
5) according to IEC 60268-1; CCIR-weighting acccording to CCIR 468-3, quasi peak; A-weighting according to IEC 61672-1, RMS